High Impact Safety Guards
High Impact Safety Guards Parameters


DiameterD - mm | HeightH - mm |
| Resistancejoules | Anchoring PulloutkN | Total Floor Spacemm | IP Grade | Flame Extinguishing Rate |
70 | 225 | 500-1000-1500-2000 | 9 369 | 190 | 94 | 59 | UL94: HB |
70 | 270 | 500-1000-1500-2000 | 9 369 | 190 | 94 | 59 | UL94: HB |
100 | 250 | 500-1000-1500-2000 | 19 360 | 190 | 140 | 59 | UL94: HB |
100 | 300 | 500-1000-1500-2000 | 19 360 | 190 | 140 | 59 | UL94: HB |
120 | 295 | 500-1000-1500-2000 | 33 950 | 190 | 183 | 59 | UL94: HB |
120 | 365 | 500-1000-1500-2000 | 33 950 | 190 | 183 | 59 | UL94: HB |
Customized solution and colours upon request

Impact Energy Information




vehicleEnergy: 17 350 J
clickOnTheImageText
exampleVehicleWeightSpeed | |
---|---|
angleApproach | 90° |
weight | 5 500 kg |
speed | 9 km/h |
vehicleEnergy | 17 350 J |
testedToBeCompliantBy BSI – PAS13 testedToBeCompliantAnd UNI 11886.
crashTestsCertified TÜV SÜDcrashTestsCertifiedAfter.
Applications
Machinery Protection
Production Lines Protection
Technology Protection
Rack Protection
Good Protection

Bad Protection

Compliant Crash Testing
We test our products in compliance with the industry's World-class standards: PAS13:2017 and UNI 11886.
We measure barriers resistance in "Joules" according to the following formula:
Kinetic Energy = 1/2*m*v² | M= Mass (Kg) and V = Velocity (Km/h)We make sure test only on real floor: armed concrete; we don't test on metal platforms.
We make sure vehicle impact takes place at the worst-scenario angle: 90°.
Finally, Bambarrier Guards is certified compliant when:
It stops the crashing vehicle safely without breaking itself and without breaking the floor.
It can be hit repeatedly without getting loose and without breaking the floor.
When after an impact, it occupies a very small space on the floor.
High Impact Safety Guards protect